!RFID TIMEOUT
Function This command sets the time delay, in milliseconds,
to wait before considering a command a failure.
NOTE: The parameters are part of a calculation and do
not translate into exact execution time differences.
Explicit Form
!RFID TIMEOUT bb,ss,rr,ww,ll
Parameters
bb
Base Time Out – Specifies the time
delay in milliseconds. The range of this
parameter is 0 through 5000.
ss
Base Time Out – Specifies the time
delay in milliseconds. The range of this
parameter is 0 through 5000.
rr
Read Time Out – Specifies the time
delay in milliseconds. The range of this
parameter is 0 through 5000.
ww
Write Time Out – Specifies the time
delay in milliseconds. The range of this
parameter is 0 through 5000.
ll
Lock Time Out – Specifies the time
delay in milliseconds. The range of this
parameter is 0 through 5000.